Description
The JA-120N can be conveniently installed in all places where an external power supply for electric lock control would be difficult to install. To module responds to a PG output of the control panel or it can be activated with a button connected to the IN input (it can be optionally locked by section control). The module is addressable and it occupies one position in the system
Technical data
Power | from the control panel BUS (9 … 14 V) 3x NiMh rechargable accumulator type AA Eneloop 1900 mAh Please note: Batteries are not included |
---|---|
External power | +12 V |
Current consumption in standby mode | 10 mA |
Current consumption for cable choice | 60 mA |
DOOR output load (Eneloop batteries) | |
Pulse (1s) | 600 mA |
Continuous | 300 mA |
Dimensions | 90 x 90 x 35 mm |
Weight | 185 g |
Operationa temperature range | -10 °C - +40 °C |
Classification | Grade 2 according to EN 50131-1, EN 50131-3, |
Operational environment according to EN 50131-1 | II. General indoor |
Also complies with | EN 50130-4, EN 55022 |