Description
It is designed for mounting in JA-19xPL multi-purpose boxes or on a DIN rail. The outputs are isolated from the bus. It is set using the DIP switch.
It is not addressable (does not occupy a position in the security system).
Technical data
Power | from control panel BUS 12 V DC (9 … 15 V) |
---|---|
Current consumption - outputs off/on | 5 mA/10 mA |
Current consumption for cable selection | 10 mA |
Maximum current from +U output (electronic fuse) | < 100 mA (all connected devices must be included in current calculations) |
Maximum switched current/voltage for each output | 100 mA/38 V |
Dimensions | 77 x 40 x 15 mm |
Weight | 26 g |
Classification | Security grade 2/Environmental class II (according to EN 50131-1) Only when installed into the JA-194PL or JA-195PL mounting box together with the JA-111H TRB module! |
Operational environment | indoor general |
Operational temperature range | -10 °C to +40 °C |
Average operational humidity | 75 % RH, non-condensing |
Certification body | Trezor Test s.r.o. (no. 3025) |
Complies with | EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50130-4 ed. 2+A1, EN 55032, EN 50581 |