Description
It features 2 power outputs (250V/5A) for control. The outputs can be set as status or impulse outputs (impulse length 1s to 10h). When an output is controlled by ringing, a limitation on the number of control events can be assigned to each phone number (suitable e.g. for various paid entrances where a phone number should have a certain credit representing the number of entries).
It has 4 inputs which respond to grounding causing reports of the off/on type in the form of SMS and ringing. Up to 100 authorized numbers can be set for control and reporting.
The GD-04K can also be locally set via USB using setting software GD-Link 2.0 or remotely via settings website.
Backed-up operation in the case of a power supply failure (for up to 24 hours) is ensured through the connection of the GD-04A backup module (sold separately).
Technical data
Power | 10.5 ÷ 15 V DC |
---|---|
Consumption in standby | approx. 25 mA (+17 mA per relay) |
Max. device consumption during GSM communication | 200 mA |
GSM module operation band E-GSM | 850 / 900 / 1800 / 1900 MHz |
GSM RF output power | 2 W for GSM 850/900 1 W for GSM 1800 / 1900 |
Triggering of inputs A, B, C, D | connection to GND |
X and Y outputs load: | |
- resistive load | max. 2.5 A/250 V AC |
- inductive (capacitive), bulb load | max. 0.5 A/250 V AC |
Safety | EN 60950-1 |
EMC | EN 301489-7, EN 55022 and EN 61000-6-3 |
Radio emissions | ETSI EN 301511 |
Operational environment | II. Indoor general (-10 °C to +40 °C) |
Dimensions (no antenna) | 76 x 110 x 33 mm |
GSM antenna connection | by SMA connector |