Description
The JA-114E allows simple control of the system using interlocking segments.
Communicates via the bus and is powered by it too.
The module has a power saving function.
The module is addressable and occupies one position in an alarm system. The menu allows for the easy control and management of sections, zones, PG outputs and reports on PG events.
Technical data
Power | from control panel digital bus (9…15 V) |
---|---|
Current consumption in standby mode | 15 mA |
Current consumption for cable selection | 100 mA |
Each additional control segment | 0.5 mA |
RFID frequency | 125 kHz |
Operating temperature range | -10 to +40 °C |
Operational environment according to EN | 50131-1 II. Indoor general |
Classification | Grade 2 |
according to | ETSI EN 300330, EN 50131-1, EN 50131-3, |
Also complies with | EN 50130-4, EN 55022, EN 60950-1 |
Can be operated according to | ERC REC 70-03 |