Description
It is installed on the ceiling and its guaranteed detection coverage is 360° with a capture radius of up to 5.5 m at a mounting height of 3.5 m.
The resistance to false alarms is adjustable at two levels
The detector has a pulse response and occupies one position in the system.
For automation functions, the detection sensitivity can be increased in the triggered system status.
A circular spacer (PLV-P-ST) has been developed as a certified accessory for ceiling mounted detectors so the bus cable can be hidden in cases where it cannot be neatly hidden in the ceiling.
Technical data
Power | from the control panel BUS 12 V DC (9 ... 15 V) |
---|---|
Current consumption: | |
- nominal consumption to calculate backup time | 2.8 mA |
- maximum consumption for cable selection | 30 mA |
Recommended installation height | 2.5 – 3.5 m above ground level |
Detection coverage | 360 °/11 m (installation height – 3.5 m) |
Dimensions | Ø 125 x 40 mm |
Weight | 120 g |
Classification | security grade 2/environmental class II (according to EN 50131-1) |
Operational environment | indoor general |
Operational temperature range | -10 °C to +40 °C |
Average operational humidity | 75 % RH, non-condensing |
Certification body | Trezor Test s.r.o. (no. 3025) |
Complies with | EN 50131-1 ed. 2+A1+A2, EN 50131-2-2, EN 50130-4 ed. 2+A1, EN 55032, EN 50581 |