Description
The detector is enrolled to two consecutive positions in the system.
The detector uses a PIR sensor for human movement detection. Breaking glass is detected by a GBS sensor, which analyses air pressure changes and sounds to detect the breaking of a glass window.
Technical data
Power | from the control panel bus 12 V (9 ... 15 V) |
---|---|
Current consumption in standby mode | 5 mA |
Current consumption for cable choise | 10 mA |
Recommended installation height | 2.5 m above the floor |
Detection angle/coverage PIR | 110 degrees/12 m (standard lens) |
Detection distance GBS | 9 m (window glass size min. 0.6 x 0.6 m) |
Dimensions | 60 x 95 x 55 mm |
Classification | Grade II |
according to | EN 50131-1, EN 50131-2-2, CLC/TS 50131-2-7-1 |
Operational environment | EN 50131-1 II. Indoor general |
Operational temperature range | -10 to +40 °C |
Also complies with | EN 50130-4, EN 55022 |