Description
The JA-112E allows simple control of the system using interlocking segments. Communicates and is powered by the bus. The module has a power saving function.
The module is addressable and occupies one position in the alarm system.
Technical data
Power | from control panel digital bus (9…15 V) |
---|---|
Current consumption in standby mode | 10 mA |
Current consumption for cable selection | 15 mA |
Each additional control segment | 0.5 mA |
RFID frequency | 125 kHz |
Operating temperature range | -10 to +40 °C |
Operational environment according to EN 50131-1 | II. Indoor general |
Classification | Grade 2 |
according to | EN 50131-1, EN 50131-3 |
Also complies with | ETSI EN 300330, EN 50130-4, EN 55022, EN 60950-1 |
Can be operated according to | ERC REC 70-03 |