Description
The module communicates and is powered via the control panel bus. It can be installed in JA-19xPL installation boxes or the control panel box.
It is not addressable (does not occupy any position in the security system).
Technical data
Power | from control panel BUS 12 V DC (9 … 15 V) |
---|---|
Current consumption (relay off/on) | 5 mA/25 mA |
Current consumption for cable selection | 25 mA |
Relay contact rating | |
Maximum switched voltage | 50 V AC/24 V DC |
Maximum switched current | 2 A |
Minimum switched current | 10 mA |
Dimensions | 78 x 40 x 15 mm |
Weight | 23 g |
Classification | Security grade 2/Environmental class II (according to EN 50131-1) Only when installed into the JA-194PL or JA-195PL mounting box together with the JA-111H TRB module! |
Operational environment | indoor general |
Operational temperature range | -10 °C to +40 °C |
Average operational humidity | 75 % RH, non-condensing |
Certification body | Trezor Test s.r.o. (no. 3025) |
Complies with | EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50130-4 ed. 2+A1, EN 55032, EN 50581 |