Description
It provides the galvanically separated switching contact of an output relay which complies with the requirements of safety isolation up to 4kV. The input is designed for a control voltage in the range 5 – 24V.
Technical data
Technical data
Operational voltage range | from 5 to 24 V DC |
---|---|
Standby current | 5 V - 80 mA, 12 V - 40 mA, 24 V - 25 mA |
Relay contact rating | |
(galvanically separated from control terminals) | protection class II |
- maximum switching voltage | 250 V AC/24 V DC |
- resistive load (cosφ=1) | max. 16 A |
- inductive, capacitive load (cosφ=0,4) | max. 8 A |
- halogen lights | max. 1000 W |
- DC | 384 W |
- minimum acceptable relay output through-wattage (DC) | 0.5 W |
Cross section of connecting wires | max. 2 x 1,5 mm2 max. 1 x 2,5 mm2 |
Dimensions, weight | 18 x 90 x 65 mm, 50 g |
Operational environment | indoor general |
Operational temperature environment | -10 °C to + 40 °C |
IP covering | IP-20 |
Also complies with | EN 50130-4, EN 55022, EN 60950-1 DIN rail EN60715 |