x

Search

JA-107KR GSM Control panel with LAN and radio module

The JA-107K is an advanced version of the JABLOTRON 100+ security system. It is designed for large living spaces, offices and businesses. It can only be installed by a trained technician with a valid Jablotron Alarms certificate.

EAN: 8595614123020

Description

It also offers flexible protection solutions for residential complexes, administrative buildings and companies that require a multi-section system. The adjustments and sizing of the system are programmed through the F-Link software (from version 2.0.0).

The JA-107K control panel offers:

  • 120 wireless and up to 230 bus devices
  • 600 users
  • 15 sections
  • 128 programmable PG outputs
  • 64 mutually independent calendar events
  • 50 user SMS reports
  • 15 user voice reports
  • 5 ARCs can be set
  • 5 selectable protocols for an ARC

The control panel has:

  • 2 mutually independent terminal boards for bus connection
  • 1 connector for a built-in radio module (JA-111R)/third terminal board - expanded using a JA-110Z-D
  • 1 connector for a GSM/GPRS communicator (JA-192Y)

The control panel also offers functions such as:

  • Maintenance
  • Day/night mode
  • Short departure response
  • Automatic setting
  • Advanced calendar features

The following products with the control panel ARE NOT COMPATIBLE:

  • JA-180A (wireless outdoor siren)
  • JA-154J (bi-directional remote control)
  • JA-190X (PSTN communicator module)

 The following products with the control panel ARE COMPATIBLE under certain conditions:

  • The JA-112E (keyboard) is compatible with FW LU61501 and higher
  • The JA-113E (keyboard) is compatible with FW LU61601 and higher
  • The JA-118N (PG Bus Output Module) is compatible with LY68003 and higher
    • FW version LY68002 and lower works only when the PG range is set in the F-Link up to a maximum value of 32
  • The JA-110I (section or PG bus indicator) is compatible only when the PG range is set in the F-Link up to a maximum value of 32

Technical data

Control panel power supply ~ 110 – 230 V/50 – 60 Hz, max. 0.85 A with fuse F1.6 A/250 V, Protection class II
Back-up battery 12 V; 7 to 18 Ah (lead gel)
Maximum battery charging time 48 h
BUS voltage (red - black) 12.0 to 13.8 V
Maximum continuous current consumption from the control panel 2000 mA permanent
3000 mA for 60 minutes
(max. 2000 mA for one BUS)
Max. continuous current consumption for back-up 12 hours Without GSM communicator LAN – OFF: 1135 mA
LAN – ON: 1107 mA
With GSM communicator LAN – OFF: 1100 mA
LAN – ON: 1072 mA
Max. continuous current consumption for back-up 24 hours Without GSM communicator LAN – OFF: 535 mA
LAN – ON: 499 mA
With GSM communicator

LAN – OFF: 530 mA

LAN – ON: 494 mA

Maximum number of devices 230
LAN communicator Ethernet interface, 10/100BASE
Dimensions 357 x 297 x 105 mm
Weight with/without AKU 7027 g/1809 g
Reaction to invalid code entry Alarm after 10 wrong code entries
Event memory Approx. 7 million latest events, including date and time
Power supply unit Type A according to EN 50131-6
T 031 note: In case of a main power failure is the system backed up for 24 hours and at the same time is a failure report sent to the ARC.
GSM communicator (2G) 850 / 900 / 1800 / 1900 MHz
Classification Security grade 2 according to EN 50131-1
Operational environment Environmental class II (indoor general) according to EN 50131-1
Operational temperature range -10 °C to +40 °C
Average operational humidity 75 % RH, non-condensing
Complies with EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50131-5-3+A1, EN 50131-6 ed. 2+A1, EN 50131-10,
EN 50136-1, EN 50136-2, EN 50581
Radio operating frequency (with the JA 11xR module) 868.1 MHz
Radio emissions ETSI EN 300 220-1,-2 (module R), ETSI EN 301 419-1, ETSI EN 301 511 (GSM)
EMC EN 50130-4 ed. 2+A1, EN 55032 ed. 2, ETSI EN 301 489-7
Safety conformity EN 62368-1+A11
Caller identification (CLIP) ETSI EN 300 089
Operational conditions ERC REC 70-03
Certification body Trezor Test s.r.o. (no. 3025)
Do you have any question? Write us

* Mandatory information