Description
It is installed on the ceiling and its guaranteed detection coverage is 360° with a capture radius of up to 5.5 m at a mounting height of 3.5 m.
The resistance to false alarms is adjustable at two levels
The detector has a pulse response and occupies one position in the system.
The mounting spacer (PLV-P-ST) is a certified accessory for ceiling detectors; these can be used with wireless detectors to separate the antenna from the mounting surface and thus to potentially improve the range.
Technical data
Power | 2x lithium batteries, type CR123A (3 V/1500 mAh) Warning: batteries are not included.
|
||||||
---|---|---|---|---|---|---|---|
Low battery voltage | < 2.4 V | ||||||
Communication band | 868.1 MHz, JABLOTRON protocol | ||||||
RF range | up to 300 m (open area) | ||||||
Recommended installation height | 2.5 – 3.5 m above the ground level | ||||||
Detection coverage | 360°/11 m (installation height – 3.5 m) | ||||||
Dimmensions | Ø 125 x 40 mm | ||||||
Weight (without batteries) | 124 g | ||||||
Classification | security grade 2/II. Indoor general (according to EN 50131-1) | ||||||
Operational environment | indoor general | ||||||
Operational temperature range | -10 °C to +40 °C | ||||||
Average operational humidity | 75 % RH, non-condensing | ||||||
Certification body | Trezor Test s.r.o. (no. 3025) | ||||||
Complies with | EN 50131-1 ed. 2+A1+A2, EN 50131-2-2, EN 50131-5-3+A1, ETSI EN 300 220-1,-2, EN 50130-4 ed. 2+A1, EN 55032, EN 62368-1, EN 50581 | ||||||
Can be operated according to | ERC REC 70-03 |