Description
The dual technology glass-break sensor reacts to air pressure changes followed by sound analysis to ensure a high immunity to false alarms.
The detection characteristic may be optimised by using alternative lenses JS-7904 LONG HALLWAY, JS 7906 PET or JS-7901 CURTAIN.
It is addressable and occupies two positions in the alarm.
Technical data
Voltage of PIR sensor | Lithium battery type CR14500 (AA) 3.6 V/2.45 Ah Please note: Batteries are not included |
---|---|
Voltage of GBS sensor | Lithium battery type CR14250 (1/2AA) 3.6 V/1.2 Ah Please note: Batteries are not included |
Typical battery lifetime | approx. 3 years (PIR sensor sleep time 5 min.) |
Communication band | 868.1 MHz, Jablotron protocol |
Communication range | approx. 300 m (open area) |
Recommended installation height | 2 - 2.5 m above floor level |
PIR sensor detection angle/detection range | 120°/12 m (with basic lens) |
Glass-break detection range | 9 m (glass min. 60 x 60cm) |
Operational environment according to EN 50131-1 | II. Indoor general |
Operational temperature range | -10 to +40 °C |
EN 50131-1, EN 50131-2-2, EN 50131-2-7-1, EN 50131-5-3 classification | grade 2 |
Dimensions, weight | 110 x 60 x 55 mm, 120 g |
Complies with | ETSI EN 300 220, EN 50130-4, EN 55022, EN 60950-1 |
Can be operated according to | ERC REC 70-03 |